Hall Effect Current Transformer

General Details

Hall Effect Current transformer is used for the measurement of current with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).

Product Highlights

  • Split Core
  • Response time < 7.0µs
  • Linearity <0.1%
  • Accuracy ±1.0%
  • Bi-directional AC, DC Current measurement

Technical Info

Hall Effect DC CT

Sr.No Part Number Rating(A) Measuring Range (A) Uni-directional or Bi-directional CT Output Voltage(V DC) Operating Temp.(°C) Measuring Accuracy (%) linearity (%) Note
1 I EPL 50DC12V 50A -50A to50A U & B 2.5±2.0 -10 °C –+85°C ±1 0.1
2 IEPL100DC12V 100A -100A to100A U & B 2.5±2.0 -10 °C –+85°C ±1 0.1
3 IEPL200DC12V 200A -200A to+200A U & B 2.5±2.0 -10 °C –+85°C ±1 0.1
4 IEPL300DC12V 300A -300A- to+300 AU & B 2.5±2.0 -10°C –+85°C ±1 0.1
5 IEPL100DC
12V4OMM
100A -100A to+100A U & B 2.5±2.0 -10°C –+85°C ±1 0.1
6 IEPL200DC
12V4OMM
200A -200A to+200A U & B 2.5±2.0 -10°C –+85°C ±1 0.1
7 IEPL300DC
12V4OMM
300A -300A to+300A U & B 2.5±2.0 -10°C –+85°C ±1 0.1
8 IEPL400DC
12V4OMM
400A -400A to+400A U & B 2.5±2.0 -10°C –+85°C ±1 0.1
9 IEPL500DC
12V4OMM
500A -500A to+500A U & B 2.5±2.0 -10°C –+85°C ±1 0.1
10 IEPL5ODC12VR 50A -50A to+50A U & B 2.5±2.0 -10°C –+85°C ±1 0.1
11 IEPL100DC12VR
12VR
100A -100A to+100A U & B 2.5±2.0 -10°C –+85°C ±1 0.1
12 IEPL100DC
12VR6OMM
100A -100A to+100A U & B 2.5±2.0 -10°C –+85°C ±1 0.1
13 IEPL200DC
12VR6OMM
200A -200A to+200A U & B 2.5±2.0 -10°C –+85°C ±1 0.1

Note:- “●” Indicates In Production CT And “■” Indicates Future Development.

Hall Effect AC CT

Sr.No Part Number Rating(A) Measuring Range (A) Auxiliary supply voltage(v) Output Voltage(V DC) Operating Temp.(℃) Measuring Accuracy (%) linearity (%) Note
1 I EPL 50AC 12V 50A 0 to 50A +12 OV-1.5V -10°C –+85°C ±1 0.1
2 IEPL100AC12V 100A 0 to 100A +12 OV-1.5V -10°C –+85°C ±1 0.1
3 IEPL200AC12V 200A 0 to 200A +12 OV-1.5V -10°C –+85°C ±1 0.1
4 IEPL300AC12V 300A 0 to 300A +12 OV-1 .5V -10°C –+85°C ±1 0.1
5 IEPL100AC
12V4OMM
100A 0 to 100A +12 OV-1.5V -10°C –+85°C ±1 0.1
6 IEPL200AC
12V4OMM
200A 0 to 200A +12 OV-1.5V -10°C –+85°C ±1 0.1
7 I EPL300AC
12V4OMM
300A 0 to 300A +12 OV-1.5V -10°C –+85°C ±1 0.1
8 I EPL400AC
12V4OMM
400A 0 to 400A +12 OV-1.5V -10°C –+85°C ±1 0.1
9 I EPL500AC
12V4OMM
500A 0 to 500A +12 OV-1.5V -10°C –+85°C ±1 0.1
10 IEPL5OAC12VR 50A 0 to 50A +12 OV-1.5V -10°C –+85°C ±1 0.1
11 IEPL100AC12VR 100A 0 to 100A +12 OV-1.5V -10°C –+85°C ±1 0.1
12 IEPL100AC 12VR6OMM 100A 0 to 100A +12 OV-1.5V -10°C –+85°C ±1 0.1
13 IEPL200AC
12VR6OMM
200A 0 to 200A +12 OV-1.5V -10°C –+85°C ±1 0.1
Applications
  • Battery chargers
  • Power Supplies
  • UPS
  • Inverter
  • Electrial Welding Machines
  • Metering Application