- Home
- Industrial
- Pure Sine Wave Inverter
Pure Sine Wave Inverter
- General Details
- Technical Info
- Applications
General Details
Inverters, as the name suggest inverts DC current to AC current. DC power is fed as input from battery banks to this inverters. full bridge topology using IGBT / Mosfets driven and controlled by DSP based microcontroller is used to convert this DC power to AC power along with other features for safe operation and better control. This AC power generated is a 50Hz pure sine wave as that of utility supply. Inverters are fully protected against output short circuits and overload conditions.
Product Highlights
- Pure sine wave output to run all appliances.
- Input and output fully isolated design.
- High efficiency up to 94%.
- Capable of driving highly reactive and capacitive loads at start moment.
- Digital signal controller based technology using MOSFET’s.
- Soft start capability for starting heavy loads.
- Protection like low input voltage, overload, short circuit, low battery indication, input – over voltage and over temperature.
- On-load switch/circuit breaker.
- Circuits like pilot generator, power stage regulator, gating pulse generator, input filter control, alarm and supervisory circuits.
Technical Info
Parameters | NVI111031EPL | INVI111061EPL |
---|---|---|
Rating | 3 KVA | 6 KVA |
Input voltage range | 44 V to 55 V DC | 44 V to 55 V DC |
Output Voltage | 230V± 4 %AC | 230V± 4 %AC |
Peak Efficiency at full load | Up to 94% | Up to 94% |
Frequency Stability | 50Hz +/- 0.1 % | 50Hz +/- 0.1 % |
Duty | Continuous | Continuous |
DC low input voltage alarm and cutoff | 44 V ± 1 V DC | 44 V ± 1 V DC |
DC high input voltage alarm and cutoff | 55V ± 1VDC | 55V± 1VDC |
LCD Dispaly | Input Voltage KVA & Working Status Fault Type Load (Amps) Input Voltage percentage (25%, 50%, 75%, 100%) Inverter ON , Inverter OFF Fault & Inverter Trip Mains Available Overload Output Voltage |
KVA & Working Status Fault Type Input Voltage percentage (25%, 50%, 75%, 100%) |
Communication Protocol | RS 232 | RS 232 |
Protections | Battery Under Voltage Battery Over Voltage Output Short Circuit Output Over Voltage DSAT 10uS (FET/IGBT- Saturation) |
Battery Under Voltage Battery Over Voltage Output Short Circuit Output DSAT 10uS (FET/IGBT- Saturation) Over Voltage |
Weight | 65 kg. | 120 Kg. |
Dimension (L x B x H) | 320 x 545 x 420 MM | 400 x 530 x 520 MM |
Applications
- Telecom Towers
- CNC Machines
- Medical Equipment
- Lighting Applications
- Fuel Pumps
- Xerox Machines
- Air Conditioners
- Refrigeration