Power Transformer

Category:
General Details

Intelux manufactures various heavy duty transformers catering to the customized requirements of its clients. Present manufacturing capacity is about 40 transformers per day. All the equipment capacities have been designed to prevent any bottlenecks in manufacturing process, backed by experienced and trained man power. Our highly qualified team of design, quality control, sales & marketing professionals are geared-up to give best quality transformers with the best services.

Product Highlights :

The manufacturing range includes:

  • Dry type vacuum (under pressure) impregnated transformers up to 1500 KVA for various industrial applications
  • 3 star & 4 star oil cooled distribution transformers up to 2000 KVA /11 KV for electricity boards/ infrastructure companies
  • Special design transformers for electricity boards/ infrastructure companies
  • Iron core Er air cored inductors and reactors
  • Rectifiers for metal finishing, electrolysis
  • Line reactors up to 1000 Amperes.
Technical Info
KVA Rating 1 KVA to 1500 KVA
Type Isolation, Auto, Open Delta.
System configuration Pri:415V3Ph,4Wire/3Ph,3W/1Ph.2W. Sec:415 V3 Ph, 4Wire/3Ph,3W/1Ph.2W.
Vector group Dy1, Dy11, DzO, Yd1, Yd11, Yyo, Ddo
Insulation class Class F, H
Duty Cycle/K rating K1, K4, K13, K20
Cooling Up to 50 KVA Natural cooling (AN) & above 50 Kva Forced Air (For ≥ 50 KVA) with Redundant fan
Efficiency 10 to 15 KVA ≥96 %, 20 to 40 KVA ≥ 97 % , 50 to 150 KVA ≥97.5%, 200 to 800 kVA : ≥ 98 %: 850 to 1500 KVA≥ 98.5%.
Regulation 10 to 15 KVA ≤4 %, 20 t o 40 KVA ≤ 3.5 % , 50 to 150 KVA ≤3.5 % 200 to 800 KVA : ≤2.5 %: 850 to 1500 KVA≤ 2 %.
Inrush current < 600% of rated current
Winding Copper & Aluminum
Core CRGO/CRNGO
ENVIRONMENTAL
Operating temperature 0 to 40  °C
Storage temperature 0 to 55  °C
Relative humidity Up to 95% (Non-Condensing)
Altitude < 1000 meter above sea level (without de-rating)
Noise <65 dB upto 160 KVA <72 dB above 160 KVA
Input isolator Switch /MCCB (optional)
PHYSICAL
Enclosure protection IP20 to Ip55
Colour finish Structure finish
Cable entry Bottom

Transformer Over sizing & Additional Harmonic loss Handling capacity

S.No K-Factor Standard oversizing in KVA rating for harmonic loading Additional harmonic Loss handling capacity in
1 K-1 None None
2 K-4 7% 14%
3 K-13 15% 32%
4 K-20 20% 44%

Remarks: Every transformer is individually designed to its specific requirements and applications

KVA Rating 25 KVA to 2000 KVA
Type Double Wound isolation
System configuration Pri: 3 Ph, 3 W/1 Ph. 2W.
Sec: 3 Ph, 4W / 1 Ph. 2W.
Vector group Dy11
Insulation Class Class A, B
Duty Cycle/K Rating K1,
Cooling ONAN
Efficiency As per Star Ratings
REGULATION
Inrush current < 600 % of rated current
Winding Copper & Aluminum
Core CRGO/amorphous
ENVIRONMENTAL
Operating Temperature 0 to 40  °C
Relative Humidity Up to 95 % (Non-Condensing)
Storage Temperature 0 to 55  °C
Altitude < 1000 meter above sea level (without de-rating) Noise< 65 dB Up to 160 KVA

Reference Standards

The transformers & reactors are manufactured in accordance with Ref IS & IEC Customer’s requirements.

IS -2026 11171 & IEC 10076 for transformers

IS -5553 & IEC 60289 for Reactors

Features
  • Compact in size
  • High efficient
  • Low power loss
  • Efficiency >98% at >40% <75% Load
  • Effective design of coil geometry to improve the heat dissipation & reduce the hot spots on the winding.
  • Effective design of core geometry to reduce the volume of the Transformer’s.
  • Transformers with the lowest possible no-load loss i.e Core loss,magnetizing currents ,and Sound level.
Applications
  • Automobile
  • Cement
  • Packaging Industries
  • Distribution & Substations
  • Hotel & Medical equipments
  • Control & APFC Panel
  • Heating Systems
  • UPS
  • Inverters Battery Chargers
  • Plating Rectifiers
  • Telecom